Page 16 - RSBPBrochure
P. 16
QUICK-ACTING SLIDE VALVE GATEX – EXPLOSION ISOLATION SYSTEM
The quick-acting slide valve GatEx is used for complete closure of a pipe, therefore it is suitable for protection of production technologies with danger
of dust explosion.
ADVANTAGES:
• Can be used for pipes above the DN 50 size
• Pressure resistance of up to 17 bar
• Extremely fast reaction time
• Short installation distance
Suitable for pneumatic conveying
lines, exhausting lines and
technologies constructed for
maximum explosion pressure
resistance (p ).
max
2014/34/EU MEETS MEETS
ATEX 114 NFPA 69
The quick-acting slide valve GatEx is activated called fail safe design that puts the slide valve
after detection of an incipient explosion. into safe state in case that its reliable function
A detector sends a signal about the incipient cannot be guaranteed (e.g. by breaking its
explosion to a control unit that in turn activates electrical supply or communication circuits,
a closing mechanism of the valve. The slide pressure decrease, etc.).
valve is closed automatically. It respects so
TECHNICAL PARAMETERS:
DN A B C D E F G H I J K L Weight
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (kg)
50 165 125 50 4 M16 230 296 175 360 104 299 804 34
65 185 145 65 4 M16 295 296 190 405 104 299 860 40
80 200 160 80 8 M16 260 296 205 450 104 299 924 47
100 220 180 100 8 M16 280 323 235 510 104 303 1004 53
125 250 210 125 8 M16 305 336 273 585 104 303 1104 58
150 285 240 150 8 M20 335 350 310 660 104 303 1204 67
16