          THERMAL IMAGING CAMERA FOR ELEVATED BODY TEMPERATURE























               PRECISE HUMAN TEM-       SIMULTANEOUS MUL-
               PERATURE MEASURE-        TIPLE PERSON FEVER
               MENT                     DETECTION              MEDICAS Key features description
                                                               Dual camera face mon-  Visual and Thermal camera face scanning in real-time with
               REALTIME ANALYSIS        HIGH MEASUREMENT       itoring        calibration
                                        PRECISION AND SENSI-
               AND ALARMS               TIVITY                 No PC needed for con-  MEDICAS Software for full real-time temperature scanning
                                                                              and control
                                                               nection
                                                                              • operating system ensures the full access to all camera
                                                               Software onboard in
                                                                               functions
          Company Workswell due to the high global risk of spre-  MEDICAS     • easy camera control via Bluetooth USB keyboard or Ethernet
          anding of infectious diseases has moved resources to   Accurate measurement  Black body radiation source included in the package for
                                                                              accurate and stable measurement in all time, real-time recali-
          build a face temperature scanning plug & play infrared              bration every 2s
          imaging solution named Workswell MEDICAS.            Thermal camera and Black Body specification
                                                               IR camera resolution  640 x 512 pixels
          That solution is based on a real-time continuous cali-  Temperature range  0 °C to +50 °C (32 °F to +122 °F) specifically calibrated for
                                                                              human face scanning
          bration using black body to achieve great accuracy and   Temperature sensitivity  Standard resolution 0.03 °C (30mK, 0.054 °F) for thermal
                                                                              differences
          stability, thermal (640 × 512 px) and RGB camera.                   ± 0.3 °C (0.54 °F)  (temperature accuracy according to refer-
                                                               Accuracy       ence blackbody at 4 m or 8 m focus distance and Black body
                                                                              calibration ROI region)
          CONTACTLESS TEMPERATURE MEASURING                    Frame rates    Exportable version worldwide (commercial) or dual use
                                                                              (commercial)
          The  thermal  camera  Workswell  MEDICAS  allows  to   Spectral range / detector  7.5 – 13.5 μm / Uncooled VOx microbolometer
    Medical
                                                                              • Standard Black body accuracy better than ± 0.08 °C (0.14 °F)
          measure  the  temperature  of  the  human  skin  and  is   Black body calibration   • High emissivity 100 mm diameter surface with precision
                                                                               digital PID
          therefore effective when the body temperature increas-  source      • Continuous camera recalibration every 2 s via black body
          es for instance due to virus infection. The average body   Lens (field of view)  • Special pyramid surface for decreasing the reflection
                                                                              45° x 37° (spatial resolution 1.308 mrad), f/1.25
          temperature on the skin surface of a healthy human is   Number of people per   Unlimited – all people are measured in the field of view in
                                                               minute
                                                                              real-time or in 4 Multi-ROI with DIO
          in the range of approximately 35.8 °C to 37 °C (96.44 °F   Digital visual camera
          to 98.6 °F). If the human temperature (measured on the   Resolution  1 920 x 1 080 pixels, 1/3” sensor for FULL HD images
          surface) exceeds 37 °C (98.6 °F), it may be an overheat-  Noise reduction  Special 3D noise reduction function with autofocus
                                                               Memory and data recording
          ing of the body or a defensive reaction of the immune               • Internal high-speed SSD 256 GB for image and video
                                                                               recording
          system to the infection of the organism  - here the sur-  Memory    • External slot for Micro SD card for taking images
          face temperature can rise up to 4 °C (7.2 °F), ie. to 41 °C         • Radiometric JPEG images and Digital camera Full HD JPEG
                                                                               images
          (105.8 °F). Accuracy: ± 0.3 °C (± 0.54 °F) (temperature   Image and video formats  • Digital camera h.264 encode video HD recording
                                                                               Encoded h.264 IR recording
          accuracy according to reference blackbody)           Interfaces & real-time remote control
                                                                              • Video streaming and camera control via MEDICAS SDK
                                                               Ethernet (RJ-45) port  • TCP/IP, RTSP server and FTP server available on the camera
            IN THE PACKAGE                                                    DIO interface accessories (4x digital outputs, 4x digital inputs,
                                                               DIO interface cable  CANH, CANL), Max inductive load 2A, Max resistive load 5A,
            Camera head with lens, focus adapter, Lens pro-    Micro USB 2.0 port  power supply +24V
                                                                              Mass storage access
            tection cap, Black body calibration source, Black   USB 2.0 port  Direct keyboard connection for MEDICAS camera control
            body Calibration certificate, Black body ball adapt-  Micro HDMI video output  1 280 x 720 pixels (720p), Aspect ratio 16:9, Micro HDMI video
                                                                              output
            er, Micro SD card, 5 m Micro HDMI cable, 2 x Pow-  Remote control system  MEDICAS OS ensures real-time control of all camera functions
            er supply adapter, 1x Software license for addition-              • Real-time temperature correction via black body source
                                                                              • Measurement functions: Automatic hot spot detection
            al Desktop data analyzing, Wireless Keyboard, USB                 • Temperature range settings: Manual to set the best visual-
                                                                               ization option
            micro OTG, Quick start guide, Hard transport case  Camera functions  • Two-level advanced alarm for illness detection with 2 differ-
                                                                               ent colors and in up to 4 Multi-ROI with DIO
                                                                              • Camera modes: Dual IR and Visible mode with real-time
                                                                               two-level alarms
   21   22   23   24   25   26   27   28   29   30   31